VersionDrift
Product

Proxmox VE 9.2.38 → 9.2.39

1 release · 1 breaking change · 0 security fixes · 0 advisories fixed

0security1breaking0deprecated2feature0fix

Breaking changes

  • breaking update the toolbar buttons of the LUN lists when the selected LUN changes on a reload. Before, Edit Entry and Remove Entry stayed enabled after the multipath entry of the LUN was removed, or disabled after one was added, until another LUN was selected, and Enable Multipath stayed enabled after… in 9.2.39

Security changes

None in the release notes.

Every release in between

9.2.39 Nov 24, 2026
otherui: guest identity: show the UID as plain text instead of in a text box that looked editable. If the guest has no UID yet, grey out the placeholder and hide the copy button.
otherpvestatd: multipath notifications:
otherkeep the highest path count of a LUN for its problem notification. Before, paths that the kernel removed before the notification was sent were missing from it, and a map left optimal with its remaining paths counted as recovered.
otheralso combine the recovery of a LUN without an expected path count, whose failed paths the kernel removed, with the recoveries of other LUNs one check apart into one notification. Before, it got a separate notification once its paths came back.
otherretry a problem notification that could not be queued only while the problem lasts. Before, it was sent later even if the LUN had recovered by then, and the recovery notification waited for it.
otherpass a defined set of fields per LUN to the notification templates, including the usable paths out of those the LUN has or should have, as Datacenter > SAN shows them. The default templates now say, for example, "2/4 paths usable" instead of "2/2 paths active (4 expected)".
featurepostinst: warn or, if possible, regenerate the NVMe host NQN and host ID that all arm64 systems installed from the Proxmox VE 9.2-1 ISO share, as NVMe over Fabrics targets identify hosts by them. If the system already uses NVMe over Fabrics and still has the static ID, only print a warning with…
otherui: cluster join: include the Proxmox VE version of the cluster in the join information, if the cluster provides it with pve-cluster 9.1.17 or newer. The join dialog then points out a version mismatch: a different minor version shows a hint to upgrade the older side first, a different major…
featureui: datacenter options: next-id: check in the edit window that the upper boundary is above the lower one, instead of only failing on save, and allow an upper boundary of 1,000,000,000, so that the range can include the highest guest ID.
otherreport: include custom QEMU CPU models.
otherui: guest summary: let the row with the status and notes panels grow to fit the status panel. Before, a status title that wrapped into a second line, for example for a container with a long name, cut off the IP addresses and their More button.
otherui: san:
othershow 'open-iscsi not installed' instead of the initiator name for nodes without open-iscsi, in the node list of the SAN view and of the guided iSCSI setup. The setup refuses to continue with such a node selected, as it cannot activate the iSCSI storage there.
otherNode > SAN > iSCSI: do not show an initiator name that a removed but not purged open-iscsi left behind.
breakingupdate the toolbar buttons of the LUN lists when the selected LUN changes on a reload. Before, Edit Entry and Remove Entry stayed enabled after the multipath entry of the LUN was removed, or disabled after one was added, until another LUN was selected, and Enable Multipath stayed enabled after…
See how far your stack has drifted from upstream. Release data from vendors’ own sources · feed under CC BY 4.0 · Code under AGPL-3.0 Settings Feed status